For contractors and integrators: we supply the devices, a line-by-line compliance table for your tender specification and the documents for handover. Tell us what the specification requires and we reply with the configuration that covers it.

The solution

One network: outdoor, indoor, one platform

The schoolyard station measures the outdoor air. The classroom stations measure the air the pupils breathe. Comparing the two shows when to ventilate, when to keep the windows shut and how much noise reaches the classroom.

Devices

Four stations, two roles

Choose one outdoor station per building and the indoor stations according to the number of rooms in the project. List prices per unit, excluding VAT.

OUTDOOR

Building-level monitoring

uRADMonitor MODEL A3 in an outdoor Stevenson shieldMODEL A3 Stevenson

MODEL A3 Stevenson

The standard outdoor station. The only one that also measures schoolyard noise.

PM1/2.5/10CO₂O₃HCHOVOCnoise dBT/RH/P
Housing
ASA Stevenson shield, IP65
Link
GSM, 10 years of data included
Power
mains adapter or 12 V solar
699 + 99 shield + 100 GSM898 USD
Request a quote for A3 Stevenson
uRADMonitor MODEL CITY mounted on the facade of Nicolae Iorga School, Cluj-NapocaMODEL CITY
Nicolae Iorga School, Cluj-Napoca

MODEL CITY

For specifications that also list traffic gases: CO, NO₂, SO₂. 1 ppb resolution.

PM1/2.5/10O₃NO₂SO₂COT/RH/P
Housing
ASA Stevenson, 25 × 20 × 10 cm, stainless mount
Link
GSM, WiFi, LoRaWAN, NB-IoT, Ethernet
Evaluation
AIRPARIF AIRLAB 2021, 2023

Does not measure noise or CO₂: pair it with an A3 in the network.

from4,499 USD
Request a quote for CITY
INDOOR

Monitoring in occupied rooms

uRADMonitor MODEL A3 in an aluminium indoor caseMODEL A3, aluminium case

MODEL A3 aluminium

The complete classroom station: every parameter typically specified, including noise.

PM1/2.5/10CO₂O₃HCHOVOCnoise dBT/RH/P
Housing
aluminium, 110 × 65 × 25 mm, 175 g
Link
GSM, 10 years of data included
Sensors
PM, O₃, HCHO plug-in, user-replaceable
699 + 100 GSM799 USD
Request a quote for A3 aluminium
uRADMonitor SMOGGIE-CO2 installed in a classroom with an explanatory panel for pupilsSMOGGIE-CO2
In a classroom, with a panel for pupils

SMOGGIE-CO2

Compact CO₂ monitor for every classroom. Shows when the room needs fresh air.

CO₂ NDIR 400–5000 ppmT/RH
Housing
42 × 43 × 27 mm, wall mount
Link
WiFi, school network
Power
5 V USB, adapter included

Uses the school WiFi: needs reconfiguring when the password changes.

per classroom239 USD
Request a quote for SMOGGIE-CO2

Optional: uRADMonitor SolarBattery for outdoor stations without mains power (10 W panel, 27 Wh battery, 12 V output). All stations are CE marked and join the same network.

Specification match

Specified parameters and the station that covers them

PDF datasheets with the compliance table, ready to attach to your offer: download them here.

Compare your tender specification with the table. If every required parameter has a ✓ in one of the chosen columns, the configuration complies.

Required parameterA3 StevensonCITYA3 aluminiumSMOGGIE-CO2
Particulate matter PM1, PM2.5, PM10✓✓✓–
Carbon dioxide CO₂✓–✓✓
Ozone O₃✓✓✓–
Volatile organic compounds VOC✓–✓–
Formaldehyde✓–✓–
Noise level (dBA)✓–✓–
Carbon monoxide CO–✓––
Nitrogen dioxide NO₂–✓––
Sulphur dioxide SO₂–✓––
Temperature, humidity, pressure✓✓✓T, RH
GSM connectivity✓✓✓WiFi
Metal housing––✓–
Operating temperature −20…+65 °C✓✓✓indoor
Recommended

Standard

  • 1 × A3 Stevenson in the schoolyard
  • 1 × A3 aluminium in each monitored room

Covers the usual specification: PM, CO₂, O₃, VOC, noise, metal housing, GSM.

Specs with traffic gases

Extended

  • 1 × CITY + 1 × A3 Stevenson outdoors
  • 1 × A3 aluminium in each room

For specifications that also list CO, NO₂, SO₂. Nitric oxide NO is not measured separately.

Lower budget

Building + classrooms

  • 1 × A3 Stevenson outdoors
  • 1 × A3 aluminium per building
  • 1 × SMOGGIE-CO2 in each classroom

CO₂ in every classroom at low cost. Check that the specification does not require all parameters in every room.

Open data

Every school gets a public dashboard

All the school's stations on one page: a daily air quality score, monthly calendar, charts, exceedance events and impact. The page is available in English and Romanian and exports to PDF for annual reporting.

Live example: Dumbrăvița School dashboard.

Raw data is available through the API in real time, for your own applications, the school website or research.

  • School management: evidence of the monitoring system for certification, PDF reports
  • Teachers: see classroom CO₂ and ventilate on time; data for science lessons
  • Parents: public page, no account needed
  • Researchers: API and historical data comparable across schools in the network
Dumbrăvița School · Air qualityillustration
SummaryChartsEventsImpact
Weekly view, daily score
Mo86
Tu81
We64
Th78
Fr42
Sa–
Su–
GoodModerateCriticalNo data

Example values. Friday: CO₂ above 1500 ppm in two classrooms after 11:00, ventilate during breaks.

Handover

What the contractor receives

  • EU declaration of conformity (CE, RED, RoHS) for each model
  • Quality and warranty certificate with each station's serial number
  • Completed compliance table for the project specification
  • Evaluation reports: AIRPARIF AIRLAB, AQ-SPEC South Coast AQMD, INCD ECOIND
  • Commissioning record with every station live on the dashboard
For designers

Vendor-neutral reference specification

Performance requirements you can paste into the tender documents.

Show the specification
TECHNICAL SPECIFICATION: Air quality, noise and thermal comfort monitoring network for school buildings

1. Network
- At least one outdoor station at building level and indoor stations in the monitored occupied rooms, all connected to one platform.

2. Parameters
- Outdoor station: PM1, PM2.5, PM10 (laser scattering); CO2 (NDIR); O3; VOC; noise level 30–130 dB; temperature, humidity, pressure. Optional: CO, NO2, SO2 with 1 ppb resolution.
- Full indoor station: the same parameters, metal housing.
- Classroom CO2 monitor (optional): NDIR 400–5000 ppm, temperature, humidity.

3. Data
- Automatic transmission and real-time public display on a school dashboard with daily score, history and PDF export; data access through a documented API.

4. Technical conditions
- CE marking and EU declaration of conformity.
- Independent metrological evaluation of the device or device family (e.g. AIRPARIF AIRLAB, AQ-SPEC SCAQMD or equivalent).
- Outdoor: UV-resistant Stevenson-type housing, IP65; operation −20…+65 °C.
- GSM connectivity with data included for at least 5 years for full stations, independent of the school network.
- Limited-life sensors replaceable without soldering.
- Warranty at least 12 months.

Equivalent equipment meeting the requirements above is accepted.
Quote

Tell us what the specification requires, get the configuration and price

Fill in the contact form with the model and the number of monitored rooms. We reply by email, where you can send us the tender specification. We come back with a compliant configuration, project pricing and the documents for your bid.

  • Shipped from stock with DHL Express worldwide
  • Stations arrive configured and start sending data when powered
  • Support with specification clarifications and handover

Magnasci SRL, maker of uRADMonitor
Str. Cocorului 23, Dumbrăvița 307160, Timiș, Romania

Phone: +40 770 420 664
Web: www.uradmonitor.com

uRADMonitor has been designed and manufactured in Romania since 2015, with stations in more than 60 countries. MODEL A3 has been evaluated by AIRPARIF AIRLAB, AQ-SPEC South Coast AQMD and INCD ECOIND and is used in many scientific studies, for example a year of indoor air monitoring in a Romanian hospital.

Questions
Is air quality monitoring in schools mandatory?

It depends on the country and the project. The EU buildings directive (2024/1275, Art. 13) requires indoor air quality monitoring devices in new zero-emission non-residential buildings and, where feasible, at major renovations. Several countries go further: Romania's green schools methodology requires a sensor network in occupied rooms, and the Netherlands requires CO₂ monitors in classrooms. This summary is for orientation, not legal advice.

Why GSM for the main stations?

School WiFi passwords change often. The data SIM included for 10 years, with international roaming, lets A3 and CITY report without setup and without the school network.

What maintenance is needed?

On the A3, the PM, ozone and formaldehyde sensors are replaced about every 2 years with a kit that fits in 20 minutes. Annual maintenance contracts are available.